Innovative and Cost-effective Technologies.
Torontech

Biofuels Testing Equipment - Semi Automatic Kinematic Viscosity Apparatus

Semi Automatic Kinematic Viscosity Apparatus

Semi Automatic Kinematic Viscosity Apparatus TT-445BZ

Semi Automatic Kinematic Viscosity Apparatus TT-445BZ conforms to ASTM D445, the Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity).

Semi Automatic Kinematic Viscosity Apparatus TT-445BZ is used to test liquid petroleum products, both transparent and opaque, by measuring the time it takes for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity, η, can be obtained by multiplying the kinematic viscosity, ν, by the density, ρ, of the liquid at a constant temperature. This method covers a range of kinematic viscosities from 0.2 to 300,000 mm²/s at all temperatures.

1. Equipped with a large LCD and an independently developed embedded temperature control system, the apparatus features an attractive and rational plastic injection integrated display screen frame. Additionally, it includes an authority management function, effectively preventing non-professionals from altering key parameters of the analyzer.

2. Features a double-layer transparent round glass constant temperature bath with a 20L glass cylinder that provides heat preservation and explosion-proof capabilities.

3. Includes a temperature correction function; however, the correction value is lost after power-off.

4. Utilizes LED lighting to illuminate the capillary line, ensuring clarity without being dazzling.

5. Comes with a dedicated viscometer holder for easy operation.

6. Offers automatic timing, calculation, and conversion to the viscosity index.

7. Equipped with an embedded thermal printer that operates quietly, quickly, and produces clear results.

1. Temperature range: Ambient to 100℃, adjustable

2. Accuracy: ±0.1℃

3. Heating power: 1.5KW

4. Test stations: 4

5. Rated voltage: AC220V±10%, 50Hz (110V also available)

6. Ambient temperature requirement: 5℃ to 40℃

7. Relative humidity: ≤85%

Configuration
No.
Name
Specification
Unit
Qty
Remark
1
Main host
Set
1
2
Thermometer
40~100℃
Piece
2
3
Portable cooling unit
Set
1
4
Stop watch
Piece
1
5
Viscometer
1.0/1.2/1.5/2.0/2.5
Set
4
As customer’s demands
6
Viscometer holder lid
Piece
4
7
Thermometer rubber plug
Piece
1
8
Power line
Piece
1
9
Fuse
Piece
2
10
User manual
Set
1
11
Certificate
Set
1
Quote Form

HOW CAN WE HELP YOU ?

Contact our sales team for a quotation.

Please Contact us for pricing, check availability, or ask for additional information about our Semi Automatic Kinematic Viscosity Apparatus
Scroll to Top