Face Mask and Protective Clothing Testing Equipment - Particulate Filtration Efficiency (PFE) Tester
Particulate Filtration Efficiency (PFE) Tester
Particulate Filtration Efficiency (PFE) Tester ToronFM-PFE is designed for quick, precise, and reliable measurement of filtration efficiency in medical and everyday protective masks, respirators, and similar items.

-
Flow Detection: The system’s test flow is supplied by external dry, clean compressed air. Internal voltage and flow stabilization mechanisms ensure consistent flow, while the automatic control system provides a simple, fast, and stable operation.
-
Test Results: Comes with a laptop and English-language software, displaying test results directly on the interface. Users can save data or export it as needed.
-
Data Port: Features an external memory card for seamless data export, eliminating concerns about data loss.
-
Resistance Detection: Measures the pressure difference of the filter material using static pressure rings in the upstream and downstream test chambers. A high-precision, imported differential pressure transmitter ensures accurate and reliable readings.
-
Ease of Use: Users simply place the filter material into the fixture and press a button to set the test flow. The system automatically measures resistance and efficiency through the controller.
Options Model
Model | ToronFM-PFE-A | ToronFM-PFE-B-1 | ToronFM-PFE-B-2 | ToronFM-PFE-C |
---|---|---|---|---|
Aerosol | Salt or Oil | Salt + Oil | Salt or Oil + Latex Spheres | Latex Spheres |
Aerosol Channel | One | Two | Two | One |
Efficiency detection | 0.1-10 μm Photometer | 0.1-10 μm Photometer 0.1 μm Particle counter |
0.1-5 μm Particle counter | |
Standards | EN149, EN143, JIS/T 8151, NIOSH-42 CFR84 | ASTM F2100 9.3, ASTM F2299 EN149, EN143, JIS/T 8151 |
ASTM F2100 9.3, ASTM F2299 | |
Control mode | Laptop computer + English operation software | |||
Oil aerosol type: DEHS, DOP, Paraffin |
Key Specifications
Model | ToronFM-PFE |
Test flow range |
30L / min ~ 100L / min, accuracy 2% 30L / min ~ 150L / min, accuracy 2% (For ASTM F2100 & F2299) |
The air flow cross-sectional area | 100cm² |
Resistance test range | 0 ~ 1000Pa, accuracy can reach 0.1Pa |
Filtration efficiency test range | 0 ~ 99.999%, resolution 0.001% |
Test time | Simultaneous efficiency and resistance test: 70s |
Test range | 0.001 - 300mg/m³ |
Voltage | Single phase 220V 50Hz (110V is also available) |
Standard Accessories
Model | ToronFM-PFE-A | ToronFM-PFE-B-1 | ToronFM-PFE-B-2 | ToronFM-PFE-C | ||
---|---|---|---|---|---|---|
Salt aerosol generator | 1 set | / | 1 set | 1 set | / | / |
Oil aerosol generator | / | 1 set | 1 set | / | 1 set | / |
Latex spheres aerosol generator | / | / | 1 set | 1 set | ||
Photometer | 1 set | 2 Sets | 1 Set | / | ||
Particle counter | / | / | 1 set | 1 set | ||
Surgical mask fixture | 1 set | 1 set | 1 set | 1 set | ||
N95 mask fixture | 1 set | 1 set | 1 set | 1 set | ||
English operation software | 1 set | 1 set | 1 set | 1 set | ||
Laptop computer | 1 set | 1 set | 1 set | 1 set | ||
Remark: 1. The accessories will be offered as per the model you selected. 2. Mask fixtures can be customized as well. |