Innovative Technologies.

Torontech

Color / Paint / Coating Test Equipment - Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

ToronSpec™-820P Benchtop Spectrophotometer  is an intelligent, user-friendly, and highly precise spectrophotometer. It features a 7-inch touch screen, full wavelength range, and operates on an Android system. With D/8° reflectance and D/0° transmittance illumination (including and excluding UV), it provides high accuracy for color measurement. Its large storage capacity and PC software integration make it ideal for laboratory use in color analysis and communication.

Bench-top Spectrophotometer ToronSpecTM-820P for Reflectance and Transmittance
Benchtop Spectrophotometer ToronSpecTM-820P for Reflectance and Transmittance

Instrument Structure Introduction

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Application

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Plastic Plate Color Measurement

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Powder Material Color Measurement

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Petroleum and Oil Color and Transmittance Measurement

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Textile and Yarn Color Measurement

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Master Batches and other Pellet Material Color Measurement

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Printing Ink and Packing Material Color Measurement

1) It uses reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials.

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

2) Dual Optical Paths Spectrum Analysis Technology

This technology can simultaneously access both measurement data and the instrument's internal environmental reference data to ensure accuracy and long-term stability.

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3) Compatible with SCI/SCE measurement, supports SCI+SCE measurement.

The instrument uses D/8 geometry, which is highly recommended by the CIE (International Commission on Illumination) to meet the color measurement needs of various industries. It supports both SCI (specular component included) and SCE (specular component excluded) modes for better detection of color changes. Fast SCI+SCE measurement has a test time of less than 4 seconds.

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

4) Rotatable Touch Screen with Android Operate System

The screen position and direction can be adjusted according to the instrument's test methods.

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

5) Open Transmittance Measurement Area, no limit on sample size

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

6) For simple measurement

It includes 15 types of standard accessories and 12 types of optional accessories to measure different kinds of materials.

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

7) Accessory Drawer to Protect and Store Accessories

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

8) Switchable Reflectance Apertures

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

9) Four Kinds of UV Test Modes for Fluorescence Material Measurement

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
Illumination/ Viewing System
Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIENo.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722ConditionC standard)
Transmittance d/0(Diffused illumination, 0 degree viewing)
Sensor
Silicon Photodiode Array
Grating Method
Concave Grating
Sphere Diameter
152mm
Wavelength
360-780nm
Wavelength Pitch
10nm
Half Band Width
5nm
Reflectance Range Resolution
0-200%
0.01%
Light Source
Pulse Xenon Lamp and LED
UV Measurement
Include UV, 400nm cut, 420nm cut, 460nm cut
Measurement Time
SCI/SCE < 2s
SCI+SCE < 4s
Measurement Aperture
Reflectance: XLAV Φ30mm, LAV 18mm,MAV Φ11mm, SAVΦ6mmTransmittance:Φ25mm
(Auto aperture size recognition)
Transmittance Sample Size
No limit on sample width and height, thickness ≤50mm
Repeatability
XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1%
XLAV Chromaticity value: Standard deviation within ΔE*ab0.015*When a white calibration plate is measured 30 x at 5-secondintervals after white calibration
Inter-Instrument Agreement
XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12tiles,at 23℃)
Illuminants
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12CWF,U30,DLF,NBF,TL83,TL84
Language
English and others
Display
Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency
Viewing Angles
2° and 10°
Color Spaces
L*a*b, L*C*h, Hunter Lab, Yxy, XYZ
Other Indices
WI(ASTM E313-00,ASTM E313-73,CIE,ISO2470/R457, AATCC, Hunter, Taube Berger, Stensby)
YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTME313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength
Color Difference
ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555shade sort
Storage Memory
8 GB U Disk for data storage and transfer
Screen Size
7 Inches Touch Screen
Power
12V/3A
Operate Temperature
5-40℃(40-104F), relative humidity 80% (at 35℃) no condensation
Storage Temperature
-20-45℃(-4-113F), relative humidity 80% (at 35℃) no condensation
Accessories
Power Adaptor, USB Cable, fixture for transmittance, U disk (PC software), Black Calibration Cavity, White and Green Calibration Tile Reflectance Test Support,30mm,18mm,11mmand 6mmapertures, reflectance sample fixture, Glass Cell 40x10mm
Optional Accessories
Heating Fixture for Transmittance, Vertical Support and Pneumatic ram for downward measurement, Reflectance fixture for small size sample, Reflectance Glass Cell Support, Corrosion-Resistant Protective Plate (non-removable), Sample Holder for Fiber, Film Fixture, Transmittance Fixture for Small Aperture, Trolley Case, European Standard Plug, American Standard Plug
Interface
USB, USB-B and RS-232
Instrument Size
465x240x260mm
Weight
10.8kgs
Other Function
1. Camera to view measurement area;
2. Support horizontal, vertical and downward measurement method(need optional accessories to support for downward measurement);
3. Auto humidity and temperature compensation function.
Options
The item code
Name
Picture
1.51.02.0029-0
Heated transmission fixtures

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.02.0030-0
Vertical stand

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.02.0013-0
Reflective cuvette holder

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.02.0033-0
Corrosion-resistant protective plates

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.02.0034-0
Fiber test cassette

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.01.0045-0
Micro transmission fixtures

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.01.0046-0
Thin film test fixtures

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.02.0035-0
820N trolley case

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.01.0069-0
12 colored bricks

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.01.0068-0
24 colored bricks

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3.02.29.0020-0
The 820N is available with an optional transmission cuvette fixture

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

1.51.01.0073-0
The 820N is available with an optional transmission cuvette fixture

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3.07.04.2002-0
810 Quartz Square Cuvette(53*45*12.5)
Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance
3.07.04.2019-0
Sintered-quartz square cuvette (outer dimensions length 43 * width 43 * height 45 mm, wall thickness 1.5 mm, optical path length 40 mm)

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3.07.04.2006-0
810 quartz square cuvette (outer dimensions length 42.5 * width 12.5 * height 45mm, arm thickness 1.25mm, optical path 10mm, clear surface 40mm)

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3.07.04.2017-0
800 quartz cylindrical cuvette (size φ64*15mm, wall thickness 2mm)

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3.07.04.2005-0
800 quartz cylindrical cuvette (size 63*40mm, wall thickness 2mm)

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

3.07.04.2014-0
33mm pathlength cuvette (outer dimensions 42.5 x 35.5 x 45 mm, wall thickness 1.25 mm, clear surface 40 mm, optical path 33 mm)

Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Quote Form

How Can We Help You?

Contact our sales team for a quotation.

Please Contact us for pricing, check availability, or ask for additional information about our Benchtop Spectrophotometer ToronSpec™-820P for Reflectance and Transmittance

Scroll to Top