Innovative and Cost-effective Technologies.
Torontech

MEDICAL DEVICES AND ANALYZERS - Fluorescent Immunoassay Analyzer

Fluorescent Immunoassay Analyzer

A cutting-edge Dry-type Novatrend - Fluorescent Immunoassay Analyzer, designed to revolutionize diagnostic testing with its advanced features and seamless functionality. This Novatrend - Fluorescent Immunoassay Analyzer ensures high-quality results within a remarkably fast timeframe of 3-15 minutes, making it ideal for emergency situations.

  • Powered by Europium-based Technology for High Quality
  • Fast Result (3-15 minutes)
  • Simple Operation (Less Training Required)
  • Objective (Results Read by Analyzer)
  • Stringent Quality Control Insure High Accuracy
  • Easy Storage Condition (4-30℃) with 2 Years Shelf Life
  • Large Memory
    Capable of storing 10,000 result records
  • High Accuracy
    Stringent Quality Control Monitoring &
    System Check Function
  • User-Friendly
    Simple Plug & Play Operation, Big LCD Touch Screen
  • Easy Operation
    Less Training Required
  • Ideal for Emergency Situations
    Lightweight, Small Size and Easy Operation
  • Time-saving
    Reading Time less than 20 Seconds
  • Get Printing Test Reports Instantly
    Built-in Thermal Printer
  • LIS Compatibility Available
  • Strong Stability
  • Extensive Test Menu
  • Cat. No.
    Product
    Specimen
    Cut-off
    Measuring Range
    Pack
    CE status
    Inflammation Marker
    FI-CRP-402
    CRP
    WB/S/P
    hsCRP: 1 mg/L, CRP: 10 mg/L
    0.5-200 mg/L
    10T/25T
    CE
    FI-PCT-402
    PCT
    0.5 ng/mL
    0.1-50 ng/mL
    FI-IL6-402
    IL-6
    10 pg/mL
    3.0-5000 pg/mL
    FI-SAA-402
    SAA
    10 mg/L
    1-300 mg/L
    Tumor Marker
    FI-PSA-302
    PSA
    S/P
    4 ng/mL
    2-100 ng/mL
    10T/25T
    Non-CE
    FI-PSA-402
    WB/S/P
    FI-FPSA-302
    Free PSA
    S/P
    /
    0.1-30 ng/mL
    FI-AFP-302
    AFP
    20 ng/mL
    5-400 ng/mL
    CE
    FI-CEA-302
    CEA
    4 ng/mL
    1-500 ng/mL
    CE
    FI-FOB-602
    FOB
    Feces
    50 ng/mL
    10-1000 ng/mL
    CE
    * FI-CA211-402
    CYFRA21-1
    WB/S/P
    <3.3 ng/mL
    1-300ng/mL
    Non-CE
    Cardiac Marker
    FI-CTI-402
    cTnI
    WB/S/P
    0.5 ng/m
    0.1-40 ng/mL
    10T/25T
    CE
    FI-CTNT-402
    0.2-40 ng/mL
    FI-NBNP-402
    NT-proBNP
    0.45 ng/mL
    0.3-22 ng/mL
    FI-CKMB-402
    CK-MB
    5 ng/mL
    0.2-75 ng/mL
    FI-HFA-402
    H-FABP
    8 ng/mL
    1-120 ng/mL
    FI-MYO-402
    Myoglobin
    90 ng/mL
    5-200 ng/mL
    FI-AMI-435
    Troponin I/Myoglobin/ CK-MB (3 in 1)
    cTnI: 0.5 ng/mL MYO: 90 ng/mL CK-MB: 5 ng/mL
    0.1-40 ng/mL 5-200 ng/mL 0.2-75 ng/mL
    * FI-AMIT-435
    Troponin T/ Myoglobin/ CK-MB Combo (3 in 1)
    cTnT:0.2 ng/mL MYO: 90 ng/mL CK-MB: 5 ng/mL
    FI-CPC-435
    Troponin I/NT-proBNP/ D-Dimer Combo (3 in 1)
    cTnI: 0.5 ng/mL D-Dimer: 0.5mg/L NT-proBNP: 0.45 ng/mL
    0.1-40 ng/mL 0.1-10mg/L 0.3-22 ng/mL
    Coagulation
    FI-DDM-402
    D-Dimer
    WB/P
    0.5 mg/L
    0.1-10 mg/L
    10T/25T
    CE
    Endocrinology
    FI-FSH-402
    FSH
    WB/S/P
    /
    1-100 mIU/mL
    10T/25T
    CE
    FI-LH-402
    LH
    1-300 mIU/mL
    FI-T3-302
    T3
    S/P
    1.23-3.08 nmol/L
    0.62-9.24 nmol/L
    * FI-T3-402
    WB/S/P
    FI-FT3-302
    FT3
    S/P
    2.6-5.7 pmol/L
    1.5-46 pmol/L
    * FI-FT3-402
    WB/S/P
    FI-T4-302
    T4
    S/P
    65-155 nmol/L
    12.87-300 nmol/L
    * FI-T4-402
    WB/S/P
    FI-FT4-302
    FT4
    S/P
    6.7-16.4 pmol/L
    1-100 pmol/L
    * FI-FT4-402
    WB/S/P
    FI-TES-302
    Testosterone
    S/P
    "Female:0-2 ng/mL, Male:2.6-12 ng/mL"
    1.0-20 ng/mL
    FI-BHCG-302
    β-HCG
    25 mIU/mL
    5-10,000 mIU/mL
    FI-BHCG-402
    β-hCG
    WB/S/P
    5 mIU/mL
    2-200,000 mIU/mL
    FI-P4-302
    Progesterone (P4)
    S/P
    /
    1.4-60 ng/mL
    Content
    Ferritin
    Male:30-400 ng/mL, Female:13-150 ng/mL
    1.0-500.0 ng/mL
    FI-TSH-302
    TSH
    0.5-5 μIU/mL
    0.1-100 μIU/mL
    FI-PRL-402
    PRL
    WB/S/P
    "Female (Non-pregnant): 2- 25 ng/mL Female (Pregnant): 10 - 209 ng/mL Male:2 - 18 ng/mL"
    1.0 - 200 ng/mL
    FI-AMH-402
    AMH
    /
    0.05-25 ng/mL
    FI-COR-302
    Cortisol
    S/P
    140 - 690 nmol/L
    50 nmol/L - 1000 nmol/L
    Cat. No.
    Product
    Specimen
    Cut-off
    Measuring Range
    Pack
    CE status
    Nephrology
    FI-ALB-102
    mAlb
    Urine
    20 mg/L
    5-300 mg/L
    10T/25T
    CE
    FI-CYSC-402
    CysC
    WB/S/P
    1.1 mg/L
    0.1-9.0 mg/L
    FI-BMG-402
    β2MG
    2.2 mg/L
    0.2-20 mg/L
    FI-NGAL-102
    N-GAL
    Urine
    10 ng/mL
    10-1500 ng/mL
    Diabetes
    FI-HBA-402
    HbA1c
    WB
    4-6%
    4-14.5%
    10T/25T
    CE
    Infectious Diseases
    FI-STA-502
    Strep A
    Swab
    /
    Qualitative
    10T/20T
    CE
    FI-FLU-502
    FLU A+B
    FI-RSV-502
    RSV
    FI-NCP-502
    COVID-19 Antigen
    20T
    FI-DEN-402
    Dengue IgG/IgM
    WB/S/P
    10T/25T
    FI-DES-402
    Dengue NS1
    FI-NCP-402
    COVID-19 IgG/IgM
    FI-CSG-402
    COVID-19 S-RBD IgG Antibody
    Semi-quantitative
    FI-CIC-525
    COVID-19 Ag/FLU A+B Combo
    NP Swab
    Qualitative
    20T
    FI-SYP-402
    Syphilis Antibody
    WB/S/P
    10T/25T
    * FI-SP-102
    Streptococcus pneumoniae
    Urine
    * FI-LEG-102
    Legionella pneumophila Antigen
    * FI-CSG-402B
    COVID-19 S-RBD IgG Quantitative
    WB/S/P
    FI-HP-602
    H. pylori Antigen
    Feces
    < 2.5 ng/mL
    2-1500 ng/mL
    FI-MAL-435
    Malaria P.f./P.v./Pan Antigen
    WB
    /
    Qualitative
    * FI-TYP-402
    Typhoid Antibody
    WB/S/P
    * FI-TET-402
    Tetanus Antibody
    0.1 IU/mL
    0.05-10 IU/mL
    * FI-ROT-602
    Rotavirus Antigen
    Feces
    /
    Qualitative
    Non-CE
    * FI-HBSG-402
    HBsAg Antigen
    WB/S/P
    <0.5 IU/mL
    0.5-200 IU/mL
    FI-HBSB-402
    HBsAb Antibody
    < 10mIU/mL
    5-1000 mIU/mL
    FI-HCV-402
    HCV Antibody
    /
    Qualitative
    * FI-MXG-402
    Monkeypox Virus Antigen
    /
    20T
    CE
    FI-HIV-402
    HIV1/2 Antibody
    WB/S/P
    10T/25T
    Non-CE
    * FI-HIG-402
    HIV P24 Antigen
    * FI-ASO-302
    Anti-streptolysin O (ASO)
    S/P
    Adults: ˂ 200 IU/mL; Children: <250 IU/mL"
    25-800 IU/mL
    CE
    Autoimmunity
    FI-IGE-402
    IgE
    WB/S/P
    100 IU/mL
    20-1600 IU/mL
    10T/25T
    CE
    * FI-IGA-402
    IgA
    0.7-4.3 g/L
    0.1-7.0g/L
    * FI-RFM-402
    Rheumatoid Factor(RF) IgM
    20IU/mL
    8-200 IU/mL
    Others
    FI-CAL-602
    Calprotectin
    Feces
    20 μg/g
    1-1000 μg/g
    10T/25T
    CE
    FI-VD-302
    Vitamin D
    S/P
    >30 ng/mL
    5-100 ng/mL
    Drugs of Abuse
    * FI-MET-102
    MET
    Urine
    1000 ng/mL
    100-5000 ng/mL
    10T/25T
    Non-CE
    * FI-MOP-102
    MOP
    /
    Quantitative
    * FI-COC-102
    COC
    300 ng/mL
    50-3000 ng/mL
    * FI-AMP-102
    AMP
    1000 ng/mL
    300-3000 ng/mL
    * FI-BZO-102
    BZO
    300 ng/mL
    150-1500 ng/mL
    * FI-APVP-102
    APVP
    /
    Quantitative
    * FI-BAR-102
    BAR
    300 ng/mL
    50-1200 ng/mL
    * FI-THC-102
    THC
    50 ng/mL
    25-150 ng/mL
    * FI-MDMA-102
    MDMA
    /
    Quantitative
    *FI-MTD-102
    MTD
    300 ng/mL
    150-1500 ng/mL
    * FI-PCP-102
    PCP
    /
    Quantitative
    * FI-OPI-102
    OPI
    2000 ng/mL
    300-6000 ng/mL
    * FI-DOA-125~195
    Multi-Drug 2~9 Drugs
    THC/COC/MET/MTD/BZO/AMP/ α-PVP/BAR/OPI/PCP/MDMA
    See Insert
    Test Method
    Dry-type Fluorescent Immunoassay
    Test Format
    Cassette
    Measurement
    Quantitative, Qualitative
    Reading Time
    < 20 Seconds
    Display
    7" LCD touch screen
    Memory
    10000 Records
    Dimensions(L*W*H)
    220*190*120 mm
    Weight
    2 kg
    Storage Conditions
    5-45 ℃, RH ≤85%
    Working Conditions
    10-30 ℃,RH ≤85%
    Printer
    Built-in thermal printer
    Power Source
    100-240VAC,50/60Hz
    Compatibility
    LIS
    Scanner
    Laser barcode scanner with USB port
    Connectivity
    USB 2 ports, LAN port, RS232 COM port (WLAN is an optional function)
    Quote Form

    HOW CAN WE HELP YOU ?

    Contact our sales team for a quotation.

    Please Contact us for pricing, check availability, or ask for additional information about our Fluorescent Immunoassay Analyzer
    Translate »
    Scroll to Top