Innovative Technologies.

Torontech

Environmental Test Chamber - HAST Highly Accelerated Stress Test Chamber

HAST Highly Accelerated Stress Test Chamber

HAST Highly Accelerated Stress Test Chamber is designed for advanced accelerated testing, evaluating a product's or material's resistance to high temperatures and humidity. It operates under specified conditions of temperature (above 100°C), humidity (65% to 100%), and pressure. HAST is a key method of environmental testing used for electrical and electronic components and devices.

The HAST Chamber is primarily used to test semiconductors, IC packaging, plastic-sealed parts, and similar materials, adhering to JESD22-A100 through A118 standards for biased (BHAST) or unbiased (UHAST) accelerated moisture resistance and pressure cooker tests. Its double-layer arc inner tank design prevents condensation and dripping, ensuring consistent results by eliminating the direct impact of superheated steam.

HAST Highly Accelerated Stress Test Chamber
HAST Highly Accelerated Stress Test Chamber
HAST Highly Accelerated Stress Test Chamber

Exterior: High-quality cold steel with a durable static color spray finish.
Interior: SUS316 matte stainless steel for exceptional resistance and longevity.
Insulation: Ultra-fine glass wool with flame-retardant grade A1 for enhanced safety.
Controller: 7-inch touch screen for intuitive operation.

Model No.

TT-HAST-35

TT-HAST-55

Interior Size (mm)

Diameter(Φ)

350

550

Depth(D)

450

650

Exterior Size (mm)

Width(W)

730

1150

Height(H)

1630

1550

Depth(D)

1100

1400

Temperature Range

 +105ºC~+135ºC

Humidity Range

65%RH to 100%(Unsaturation control)

100%RH (Saturation control )

Pressure Range

0.05~0.3MPa

Gauge pressure: +0.2~200kPa

Absolute pressure: 100 ~ 300kPa

Temperature Fluctuation

± 0.5°C

Temperature Uniformity

≤ 3.0°C

Temperature Deviation

≤ ±3.0°C

Humidity Fluctuation

±3.0% RH

Humidity Deviation

±5.0% RH

Pressure Deviation

≤ ±2kPa

Heating Rate 

±25ºC~+135ºC within 45 min

(average in whole process) ( no-load,no heating)

Pressurization Time

Normal Pressure ~200kPa within 20 min

Voltage

 220V AC 1Ø 50Hz (110V is also available)

Noise

≤68dB (1 meter distance from the door)

Safety Protection Device

NFB (No fuse breaker), over pressure, overheat and over current protectors for compressor, over temperature protectors, overload protector of fan, dry heat protector, short of water protector.

Quote Form
Please Contact us for pricing, check availability, or ask for additional information about our HAST Highly Accelerated Stress Test Chamber
Scroll to Top