Innovative and Cost-effective Technologies.
Torontech

ScopeX CS Desktop Spectrometer Family - ScopeX benchtop XRF Analyzer with Vacuum

ScopeX benchtop XRF Analyzer with Vacuum

The ScopeX benchtop XRF Analyzer with Vacuum, caters to laboratories seeking high sensitivity and precision in analysis. It merges sophisticated spectroscopic analysis technology with a vacuum system, enabling detailed elemental analysis of diverse materials. 

The ScopeX benchtop XRF Analyzer with Vacuum embodies advanced design principles, featuring a compact body size, spacious sample compartment, and outfitted with intelligent software and top-notch hardware. Capable of detecting samples in various forms like solids, powders, films, etc., as well as in block, flake, or linear configurations.

ScopeX benchtop XRF Analyzer with Vacuum
ScopeX benchtop XRF Analyzer with Vacuum

Minerals and Mining

ScopeX benchtop XRF Analyzer with Vacuum

Cement and Building materials

ScopeX benchtop XRF Analyzer with Vacuum

Ceramics, glass and industrial materials

ScopeX benchtop XRF Analyzer with Vacuum

Coal ash, catalyst

ScopeX benchtop XRF Analyzer with Vacuum

Metal material

ScopeX benchtop XRF Analyzer with Vacuum

Petroleum chemical industry

High performance configuration

The low-energy X-ray, combined with an intelligent vacuum system, exhibits excellent excitation effects on light elements such as Si, P, S, Al, and Mg. XRF technology is capable of analyzing high concentrations of critical elements like Cr, Ni, and Mo.

A variety of collimator, filter automatic switch

The ScopeX benchtop XRF Analyzer with Vacuum offers four types of collimators: 5mm, 3mm, 1mm, and 0.5mm. The software enables automatic switching between collimators and filters, streamlining processes and saving time and effort. By selecting the appropriate combination of collimator and filter, detection accuracy and sensitivity can be enhanced.

Nondestructive testing

The entire testing process is conducted without causing any damage or interference to the performance of the tested object.

Peltier refrigeration

Using Peltier electric refrigeration instead of liquid nitrogen reduces the complexity of the device and helps save on manpower and equipment maintenance costs.

Data transmission

Data transmission can be achieved through various methods including USB, WiFi, wireless Bluetooth, and other wireless technologies.

User-defined

The file can be saved in formats such as Excel, PDF, and others. Users have the option to customize the test report, incorporating elements like company logos, spectral spectra, and other sample information.

Safety

The ScopeX benchtop XRF Analyzer with Vacuum features a fully enclosed metal chassis and a leakage protection switch, ensuring radiation safety in accordance with international standards.

Test object
Solid, liquid, powder
Range of element
Na—U
Sample room size
304×368×78mm(L×W×H)
Sample weight range
0-2.5KG
Cover open
Automatic
Mainframe size
570×400×400mm(L×W×H)
Mainframe weight
64KG
X-ray tube
High power side window X-ray tube
Voltage
Up to 50kV
Current
Maximum 1mA
Cooling Method
Air cooling
Detector
SDD
Sampling Method
Hand sampling, Auto injection
Sample Observation
5 megapixel HD industrial camera
PC(CPU)
CPU is I3-7100 with the same main frequency or above
RAM
DDR4 4 GB memory or above
ROM
1TB HDD or 256GB SSD or above
OS
Windows 10
Temperature conditions
10°C~35°C
Relative humidity
40%-70% (No condensation)
Power supply
220VAC (110V also available)
Rated power
600W
Quote Form

HOW CAN WE HELP YOU ?

Contact our sales team for a quotation.

Please Contact us for pricing, check availability, or ask for additional information about our ScopeX benchtop XRF Analyzer with Vacuum
Translate »
Scroll to Top