What Is a Disintegration Test?

What Is a Disintegration Test

A disintegration test checks how quickly a tablet or capsule breaks down into smaller particles in a liquid medium that simulates the body’s environment—usually at body temperature (37 ± 2°C).

Why does this matter? Because disintegration is the first step toward drug release and absorption. If a tablet doesn’t disintegrate properly, the active ingredient may not be released at all, resulting in poor efficacy and potential safety concerns.

This test is especially crucial for immediate-release dosage forms, which are meant to act fast. In fact, the disintegration test USP guidelines require most tablets to disintegrate within 30 minutes.

Disintegration vs. Dissolution: What’s the Difference?

Disintegration vs. Dissolution - What’s the Difference

If you’re wondering about the difference between disintegration and dissolution tests, here’s a quick breakdown:

  • Disintegration measures how fast a tablet or capsule breaks apart.
  • Dissolution measures how fast the drug dissolves into a solution.

You can think of disintegration as the mechanical breakup, and dissolution as the chemical process that follows. Both are essential, but for some highly soluble drugs, regulatory guidelines even allow disintegration to replace dissolution testing.

That’s why many companies are exploring the benefits of disintegration and dissolution test strategies together—to better understand drug performance and streamline quality control.

What Does a Disintegration Test Machine Do?

What Does a Disintegration Test Machine Do

Disintegration test machine is a lab instrument designed to carry out the test under controlled conditions. It replicates the movement and temperature of the gastrointestinal environment to see how long a tablet or capsule takes to fall apart.

Key Disintegration Tester Parts Include:

  • Basket-rack assembly: Holds up to six tubes for testing multiple samples at once.
  • Glass tubes: Open-ended, fitted with wire mesh at the bottom to catch residue.
  • Wire mesh screens: Typically 2.0 mm openings with 0.6 mm wire diameter.
  • Heated water bath: Maintains a consistent temperature (usually 37 ± 2 °C).
  • Motorized lift mechanism: Moves the basket up and down 29–32 times per minute.
  • Auxiliary disks: Help keep tablets submerged, especially for coated or buoyant products.

If you’re looking for a modern and reliable option, Torontech’s Disintegration Tester is built to meet USP, EP, and JP standards. And it’s designed for ease of use, precision, and robust daily operation.

Disintegration Test Procedure: Step by Step

Disintegration Test Procedure - Step by Step

Running a disintegration test may seem straightforward, but precision and consistency are key. The process is governed by well-defined standards, such as USP <701> and USP <2040>, which outline how the test should be conducted to ensure valid and repeatable results.

Here’s a step-by-step overview of how the procedure works in practice:

1. Insert the Samples

Begin by placing one dosage unit—a tablet or capsule—into each of the six vertical glass tubes in the basket-rack assembly. These tubes are open at both ends and fitted with a fine wire mesh at the bottom to retain particles for observation.

Each sample must be handled carefully to avoid chipping or pre-test damage, which could affect the outcome.

2. Prepare the Test Medium

Fill the beaker with the appropriate immersion fluid, commonly water, simulated gastric fluid (SGF), or simulated intestinal fluid (SIF), depending on the product type. Heat the medium to 37 ± 2°C to simulate body temperature. This step is critical, as even minor temperature fluctuations can affect disintegration time.

3. Start the Test

Lower the basket-rack assembly into the beaker of heated fluid. The apparatus will then begin its motion, moving the basket up and down in a smooth, rhythmic cycle, typically 29 to 32 cycles per minute.

This motion mimics the peristaltic movements of the gastrointestinal tract, helping assess how the dosage form behaves in the body.

4. Observe and Record

Monitor the samples throughout the test duration, usually 30 minutes for uncoated tablets and up to 60 minutes for coated or enteric formulations.

The endpoint is defined as the point at which no residue of the original tablet or capsule remains, except for fragments of coating or a soft, mushy mass with no firm core.

Make sure to record:

  • The total time taken for complete disintegration
  • Any anomalies, such as delayed breakdown or undissolved fragments
  • Whether auxiliary disks were used

5. Use Auxiliary Disks (When Needed)

For certain products, such as film-coated tablets, enteric-coated tablets, or low-density capsules that float, you’ll need to use auxiliary disks. These small, transparent plastic disks sit atop the dosage unit within each tube, ensuring the sample stays submerged throughout the test.

Without them, some formulations might not fully interact with the test fluid, leading to false failures or inconsistent results.

Disintegration Test for Tablets and Capsules

You might be wondering about the specific disintegration test for tablets and capsules. Here’s how it breaks down:

Tablets:

  • Immediate-release tablets must disintegrate within 30 minutes in water or SGF.
  • Coated tablets are tested with auxiliary disks and given up to 60 minutes.
  • For enteric-coated tablets, there’s a two-stage test—first in acidic medium, then in buffer.

Capsules:

  • Hard gelatin capsules must disintegrate within 20 minutes.
  • Softgel capsules are tested using a rupture method or in water, depending on formulation.
  • For some formulations, if one capsule fails, you’ll retest with an additional 6 units to verify.

The disintegration process ensures that the dosage form breaks down completely, critical for bioavailability and therapeutic effect.

Acceptance Criteria for Disintegration Test

The acceptance criteria for disintegration tests are both clear-cut and strictly enforced, because they are designed to ensure consistent product performance, regulatory compliance, and patient safety.

According to the United States Pharmacopeia (USP), here’s how the evaluation works:

  • All 6 out of 6 dosage units (tablets or capsules) must fully disintegrate within the specified time frame to automatically pass.
  • If 1 or 2 units fail, the test doesn’t immediately fail, but it does trigger a retest with 12 additional samples from the same batch.
  • If, in total, at least 16 out of 18 units (from the original 6 + the retest group) disintegrate within the allowed time, the product still meets the disintegration test acceptance criteria.
  • If 3 or more of the initial 6 fail—or if fewer than 16 of 18 disintegrate within the time limit—then the batch is considered non-compliant and requires investigation or corrective action.

These criteria apply across a wide range of oral solid dosage forms, with minor variations depending on whether the product is an immediate-release, coated, enteric-coated, or capsule formulation.

It ensures uniform performance from unit to unit and batch to batch, helping you catch formulation or process inconsistencies early. By adhering to this system, you reinforce quality assurance, strengthen consumer trust, and reduce the risk of costly product recalls or regulatory penalties.

Final Thoughts

Now that you know what a disintegration test is, how it works, and why it matters—you can see just how essential it is to your pharmaceutical or nutraceutical operations.

It’s not just a regulatory box to check. It’s a vital quality control tool that protects your product, your brand, and ultimately, your patients or customers.

With a dependable disintegration tester, like the one from Torontech, you’ll have the confidence to meet standards, troubleshoot issues, and move your products forward with precision.

Index